|    Inquiry
 
Products

4  Rapid Thermal Process
 
·LEDs Production RTA RTP-AW810
·Refurbished AG Heatpulse 210
·Refurbished AG Heatpulse 410
·Refurbished AG Heatpulse 610
·Refurbished AG Heatpulse 21XX
·New AccuThermo AW 810M
·New AccuThermo AW 610
·New AccuThermo AW 410
4  Plasma Asher Stripper Descum
 
·Refurbished Matrix 205
·Refurbished Gasonics Aura 3010
·Refurbished Branson IPC 3000
·Refurbished Matrix 10
·Refurbished Gasonics L3510
·Refurbished GaSonics Aura 2000LL Loadlock Asher
·Branson IPC L3200-Long time Plasma Asher Process
·Refurbished Gasonics Aura 1000
·Refurbished Matrix 105
4  Plasma Etch
 
·Lam Autoetcher 590
·Lam AutoEtch Lam 490
·Refurbished Tegal 901e
·Refurbished Matrix 303
·Refurbished Matrix 403
·Refurbished Gasonics AE 2001
·Lam Rainbow 4520 Oxide Etch
·Lam Rainbow 4428 for Plasma Etch
·Lam Rainbow 4420 Plasma Etch
4  Reactive ion etching (RIE)
 
·Plasma Therm VII 70 Series
·Refurbished STS 320 RIE
4  PECVD
 
·Refurbished STS 310 PECVD
4  Inductively coupled plasma (ICP)
 
·Refurbished STS 320 ICP
4  Metrology & Inspection
 
·Hitachi S8840 Scanning Electron Microscope
·XFlash® QUAD 5040 Detector
·XFlash® 5030 Detector
·XFlash® 5010 Detector
·Energy Dispersive X- Ray Spectrometer QUANTAX 200
·LEO FE-SEM model 982
·Micrion FIB model M9500
·Hitachi FE-SEM model S-4160
·Hitachi FE-SEM model S-4700
·Hitachi S-4500 SEM Cold Field Emission SEM System
·Hitachi S-8820 CD SEM
·Hitachi S-9300 CD SEM_SDI
·Hitachi S-4800 SEM Cold Field Emission SEM System
4  Misc.
4  Backside Equipment
4  Lab Equipment
 
·Muffle Furnaces (400-1800C)
·Tube Furnaces (1-5 Zone)
·Hi-Pressure Furnace
·RTP Furnaces
·Dental Sintering Furnaces
·Induction heaters&CZ grower
·Lab Ovens / Hot Plates
·Melting Furnaces
·Cutting / Dicing Saws
·Polishing Machines
·Desktop Machine-shop
·Glove Box
·Film Coaters
·Lab Press & Rollers
·Laboratory Mill / Mixer
·Battery / Capacitor Analyzers
·Desk-Top X-Ray Instruments
·Digital Microscopes
·DI Water / Ultrasonics
·UV Equipment & Adhesives
·Lab Ware / Accessory
·Round Wafer Carriers
·Sticky & Film Boxes
·IC Tray & Plastic Boxes
·Vacuum Pen&Tweezers
4  Electrical Test and PCM Software
 
·Electronic Tester List
·Temptronic TP03500
·HP 4142B
·Refurbished HP 4145B
·Refurbished HP 4062UX
·Refurbished HP 4155
4  Sputtering and Evaporator System
 
·Upgrade MRC903A Sputter System
4  Lithography & Photoresist
 
·IOS.Cube 6 | Series
·IOS.Cube 5 | Series
·IOS.Cube 3 | Series
·IOS.Cube 2 | Series
·IOS.Cube 1 | Series
4  Wet Processing
 
·SV-702 Spin Rinse & Dryer (SRD) system
·SV-802 Spin Rinse & Dryer (SRD) system
·ASD-SH-802 Horizontal Spin Dry-In
4  Wafer Probers
 
·Refurbished EG 4085X
·Refurbished EG 1034
·Refurbished EG 2001
·Refurbished MP 2020
·Refurbished EG 2010
4  Chiller
4  Pump
4  RF Power
4  Oven
4  Gas Cabint
4  Inventory on Sale
4  Gallium Nitride Material
 
·free-standing GaN substrate
·GaN Templates
4  Bulk Equipment on sale
 

Inventory >> Plasma Asher Stripper Descum >> Drytek Megastrip 6 H.F.

Drytek Megastrip 6 H.F.

Click to Enlarge

Manufacturer:Drytek

Condition:used,complete,good condition

Price:$1,500.00,AS IS,WHERE IS,Advanced Payment

 

 

Used DRYTEK  MEGASTRIP 6  H.F. Photoresist Stripper. Features a large capacity, aluminum chamber that processes up to 25 - 8 in. wafers, 50 - 6 in. wafers, 75 - 5 in. wafers, 100 - 3 in. or 4 in. wafers. Chamber: 14 in. H x 23 in. W x 13 in. D. 1000W, Solid State 13.56 MHz. Process Controls: Fully automatic operation. Microprocessor control. Digital displays including RF power. Process time, chamber pressure, and mass flow.

 

  

Plasma Asher Stripper Descum

In semiconductor manufacturing plasma asher/stripper is the process of removing the photoresist from an etched wafer. Using a plasma source, a monatomic reactive species is generated. Oxygen or fluorine are the most common reactive species. The reactive species combines with the photoresist to form ashing which is removed with a vacuum pump.

Typically, monatomic (single atom) oxygen plasma is created by exposing oxygen gas (O2) to ionizing radiation. At the same time, many free radicals are formed which could damage the wafer. Newer, smaller circuitry is increasingly susceptible to these particles. Originally, plasma was generated in the process chamber, but as the need to get rid of free radicals has increased, many machines now use a downstream plasma configuration, where plasma is formed remotely and channeled to the wafer. This allows electrically charged particles time to recombine before they reach the wafer surface, and prevents damage to the wafer surface.

Monatomic oxygen is electrically neutral and although it does recombine during the channeling, it does so at a slower rate than the positively or negatively charged free radicals, which attract one another. Effectively, this means that when all of the free radicals have recombined, there is still a portion of the active species available for process. Because a large portion of the active specie is lost to recombination, process times may take longer. To some extent, these longer process times can be mitigated by increasing the temperature of the reaction area.

Allwin21 Corp can provide the following refurbished plasma asher/descum equipment.


Home | Company | Products | Service | Spare Parts | Contact Us | News
Allwin21 Corp. Phone:001-408-988-5188 Fax:001-408-9047168 3251 Leonard Court Santa Clara,CA 95054 e-mail:sales@allwin21.com
Copyright © 2000-2006 Allwin21,Corp. All Rights Reserved